Small Business / Woman Owned, HUB Certified - State of Texas
23230 Sandsage Lane
Katy, Texas 77494-4207
Phone: (281) 394-2311
Fax: (281) 394-2522
Home
Manufacturers
Apron Check Software
Contact Us
About Us
Medical Instruments
Diagnostic Radiology
Dosimetry
Hand Held Survey Meters
Health Physics
Lead Aprons
Mammography
Medical Physics
Nuclear Medicine
Radiation Safety
Radiation Therapy
Radiation Survey Meters
Tables and Accessories
Ultrasound
X-Ray Test Devices
Homeland Security
Area Monitors
Response Kits
Hand Held Survey Meters
Portal Monitors
Waste Monitors
Gate Monitors
Personal Dosimeters
Special Equipment
Calibration Services
Scintillation Detectors
Continuing Education
Nursing
Radiology
Software
Lead Apron Inspection
Health Physics :
PRIMALERT™ Digital Area Monitors
PRIMALERT
Digital Area Monitors
Model 05-443 and 05-444
LED digital display
Low and high alarm indicators
Programmable alarm indicators
Optional remote
Detector fail indicator
Battery backup
Data output / RS-232
Two configurations available with internal energy compensated GM detectors
CE tested. Meets applicable standards
Specifications:
Internal GM Detector Range:
Item 337-443: 0.1 mR/hr to 1 R/hr Item 337-444: 1 mR/hr to 4 R/hr
Display:
4 digit LED display with 0.8 in (2 cm) character height
Display Range:
000.0 to 9999
Display Units:
Can be made to display in µR/hr, mR/hr, R/h, µSv/h, mSv/h, Sv/h, cpm, cps and others
Linearity:
Reading within ± 10% of true value with detector connected
Response:
Typically 3 seconds from 10% to 90% of final reading
Status:
(green light) Indicates the instrument is functioning properly
Low Alarm:
Indicated by a yellow light and slow beep (1 per sec) audible tone (can be set at any point from 0.0 to 9999)
High Alarm:
Indicated by a red light and fast beep (4 per sec) audible tone (can be set at any point from 0.0 to 9999)
Note:
Audible indicators can be configured as a single beep if desired.
Detector Fail:
(red light and audible tone: > 68 dB at 2 ft) Indicates detector overload, no count from detector, or instrument failure
Low Battery:
(yellow) Indicates < 2 hours of battery power remaining
Calibration Controls:
Accessible from front of instrument (protective cover provided)
High Voltage:
Adjustable from 200 to 2500 V
Threshold:
Adjustable from 2 to 100 mV
Dead Time:
Adjustable to compensate for dead time of the detector and electronics (can be read on the display)
Overload:
Senses detector saturation (indicated by display reading “OL”)
Overrange:
Indicates the radiation field being measured has exceeded the counting range of the instrument (indicated by display reading “- - - “)
Data Output:
9 pin connector providing 5 decade log output, RS-232 output, signal ground connection, FAIL and Alarm signals (current sink), and direct connection to battery and ground
Power Requirements:
95 to 135 VAC, 50 to 60 Hz single phase (<100 mA), 6V sealed lead acid rechargeable battery (built-in)
Battery Life:
Typically 48 hours in non-alarm condition, 12 hours in alarm condition
Battery Charger:
Battery is continuously trickle charged when instrument is connected to line power and turned on Construction: Aluminum housing with white polyurethane enamel paint
Temperature Range:
-4° to 122° F (-20° to 50° C). May be certified for operation from -40° to 150° F (-40 to 65° C)
Size:
9.7” W x 2.5” D x 7.4” H
Weight:
6.5 lb
Optional Remote Display
Status:
(green light) Indicates the instrument is functioning properly
High Alarm:
(red LED) Indicates the radiation level exceeds the high alarm point
Detector Fail:
(red LED) Indicates detector overload, no count from detector, or instrument failure
Audio:
Unimorph type with ON/OFF switch (> 68 dB at 2 ft)
Power Requirements:
Provided by PRIMALERT (20 ft cable included)
Construction:
Aluminum housing with ivory polyurethane enamel paint
Temperature Range:
-4° to 122° F (-20° to 50° C)
Size:
6” W x 2” D x 7” H
Weight:
1.5 lb
CE Tested
Site created & maintained by
Tux Studios.Com
© Owens Scientific, Inc., Houston,Texas
Advanced Search
New Items
Dual Purpose Table
Accommodates Ultrasound and Echocardiography Procedures
Next Generation Spectroscopic PRD
Small - Pocket Sized
Inovision Model 451B
Ion Chamber Survey Meter with Beta Slide
Unfors DXR+
Direct X-ray Ruler